Efficiency of Synchronous and Asynchronous Buck-Converter at Low Output Current.

Main Article Content

Ismael Khaleel Murad

Abstract

In this paper both synchronous and asynchronous buck-converter were designed to work in continuous conduction mode “CCM” and to deliver small load current. Then the two topologies were tested in terms of efficiency at small load current by use of  different values of switching frequencies (range from 150 KHz to 1MHz) and three separated values of duty-cycle (0.4, 0.6 and 0.8).  


Obtained results turns out that efficiency of both synchronous and asynchronous buck-converter “switching step-down voltage regulator” responds in a negative manner to the increase in the switching frequency. However, this impact is being stronger in synchronous topology because of magnifying effect of losses related to switching frequency compared to those related to conduction when working at small load currents; this behavior makes obtained efficiency of both topologies in convergent levels when they operated to deliver small output current especially when working with higher switching frequencies. Larger duty-cycle can rise up the efficiency of both topologies.

Downloads

Download data is not yet available.

Article Details

How to Cite
[1]
“Efficiency of Synchronous and Asynchronous Buck-Converter at Low Output Current”., JUBES, vol. 27, no. 2, pp. 194–206, Jun. 2019, doi: 10.29196/jubes.v27i2.2337.
Section
Articles

How to Cite

[1]
“Efficiency of Synchronous and Asynchronous Buck-Converter at Low Output Current”., JUBES, vol. 27, no. 2, pp. 194–206, Jun. 2019, doi: 10.29196/jubes.v27i2.2337.

Similar Articles

You may also start an advanced similarity search for this article.